SATISFIED CUSTOMERS
WHO TRUST OUR SERVICE

REQUEST A QUOTE

UNUSED POTENTIAL

Thermography identifies defects down to the single cell. This enables identification of existing defects that cannot be identified by conventional measurements. In particular, it also helps identify emerging defects at an early stage. This allows direct recommendations for action to optimise earnings and improve the performance ratio.

3 MWp SOLAR PARK

"MORE" EARNING POTENTIAL PER YEAR 5.900€
COSTS FOR THE INSPECTION
2.700€

"I never realised how much my company missed out on in recent years. Regular checks in future will ensure that this will not happen again."

Sebastian Römer

Type of fault
Module output in watts
kWh / kW per year
Yield reduction per year in kWh
Financial loss per year
Financial loss after 13 years
7 x Module with hotspot
275 W
900
87 kWh
25 €
320 €
30 x PID
275 W
900
1.114 kWh
317 €
4.116 €
15 x failed substring
275 W
900
2.228 kWh
633 €
8.233 €
7 x failed string
275 W
900
17.325 kWh
4.926 €
64.031 €
Sum
20.754 kWh
5.901 €
76.700 €
Cost analysis of the PV system without repairing the identified faults.

Calculated yield reduction at a feed-in tariff of €0.28/kWh, a module output of 275 W, and a feed-in of 900 kWh/kW. Module costs of 40 cent/watt, repair time of 30 min/module for 2 persons, and an hourly wage of 50 EUR, travel costs of 200 EUR.

12 MWp SOLAR PARK

"MORE" EARNING POTENTIAL PER YEAR 41.245€
COSTS FOR THE INSPECTION
6000€

"The results of the inspection really took me by surprise. The additional profit of just under 41,000 euros will be reinvested sensibly."

Stefanie Heinze

Type of fault
Module output in watts
kWh / kW per year
Yield reduction per year in kWh
Financial loss per year
Financial loss after 13 years
51 x module with hotspot
215 W
900
3.294 kWh
988 €
9.880 €
1051 x module with defective bypass diode
215 W
900
91.512 kWh
27.454 €
274.540 €
389 x PID
215 W
900
25.092 kWh
7.527 €
75.270 €
8 x failed module
215 W
900
2.106 kWh
632 €
6.320 €
4 x failed string
215 W
900
15.480 kWh
4.644 €
46.440 €
Sum
137.484 kWh
41.245 €
412.450 €
Cost analysis of the PV system without repairing the identified faults.

Calculated yield reduction at a feed-in tariff of €0.28/kWh, a module output of 275 W, and a feed-in of 900 kWh/kW. Module costs of 40 cent/watt, repair time of 30 min/module for 2 persons, and an hourly wage of 50 EUR, travel costs of 200 EUR.

A UCAIR INSPECTION
IS INCREDIBLY SIMPLE

A solar park inspection can be scheduled and carried out at short notice. All that’s needed are good weather conditions and access to the site. The photovoltaic inspection with drones can be carried out completely independently and does not require any further technical requirements on the part of the solar park operators or solar asset management.

HOW IT WORKS
Earnings calculator

EARNINGS CALCULATOR

Do you know how much more money you can earn if you have your solar installation checked?

Enter your system capacity and feed-in tariff and discover how much additional yield potential is hidden within your system.

System capacity:
kWp
Feed-in tariff:
Condition of the system:
normal poor   very poor

Normal: The PV system has some minor technical defects

Poor:The PV system has some significant anomalies that reduce efficiency

Very poor: The PV system has considerable defects, e.g. failed strings

Possible additional annual yield:
{{yield}}